The DT4281 is our top-of-the-line high-precision 60000 count digital multimeter with all of the functions and features required for advanced testing in complex power and electrical applications.

 

Key Features

• 60000 count, 5-digit display, high-resolution measurements

• ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics

• Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)

• Includes multiple measurement functions such as DC+ACV, temperature, capacitance, and frequency

• Includes terminal shutter mechanism for accident prevention (prevents erroneous test lead insertion)

• Measures large currents with optional clamp probe (only for DT4281, which has no 10 A terminal for accident prevention)

• USB communications function supports PC measurements (optional)

• Broad -15 (5°F) to 55°C (131°F) operating temperature range CAT IV 600 V, CAT III 1000 V

 

DC voltage 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt.
AC voltage 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3)
DC + AC voltage 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3)
Resistance 60.000 Ω to 600.0 MΩ, 8 ranges, Basic accuracy: ±0.03 % rdg. ±2 dgt.
DC current 600.00 μA to 600.00 mA, 4 ranges
Basic accuracy: ±0.05 %rdg. ±5
dgt.
AC current 600.00 μA to 600.00 mA, 4 ranges
Basic accuracy 45 - 65 Hz : ±0.6 %rdg. ±5
dgt. (True RMS, crest factor 3)
Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range)
AC Current (use with Clamp on probes) 10.00 A to 1000 A, 7 ranges
Add the Clamp on probe accuracy to Basic accuracy 40 - 65 Hz : ±0.6 %rdg. ±2
dgt. (True RMS, crest factor 3)
Peak DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)
AC V, DC/AC A measurement: 
Signal width 1 msec or more (single), 250 μsec or more (repeated)
C (capacitance) 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt.
Continuity Check Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more
Diode test Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages
Frequency AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)
99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 %rdg. ±3
dgt.
dB conversion Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages
Display dB conversion value of AC voltage (dBV)
Temperature (thermocouples) K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F) 
Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 %rdg. ±3 °C
Other functions Filter function (Remove harmonic noise, use only at 600 VAC, 1000 VAC ranges), Display value hold, Auto hold, Max/Min value display, Sampling select, Relative display, Measurement memory (400 data), Auto-power save, USB communication (option), 4-20 mA % conversion
Display Main and sub displays: 5-digits LCD, max. 60000 digits
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s )
Power supply LR6 (AA) alkaline batteries × 4, Continuous use: 100 hours
Dimensions and mass 93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries)
Accessories Test Lead L9207-10 × 1, Instruction Manual × 1, LR6 Alkaline Battery × 4
 

The ultimate digital multimeter, featuring a safe design that’s ideal for use in electrical work

The DT4281, which is part of Hioki’s DT4280 series of high-end digital multimeters, is designed for maximum safety in electrical work. An AC clamp can be connected to allow safe current measurement. ・ DC current measurement 600.00μA / 6000.0μA / 60.000mA / 600.00mA ・ AC current measurement 600.00μA / 6000.0μA / 60.000mA / 600.00mA ・ Accepts an AC clamp sensor.

 

 

 

 

 

 

Measure output voltage on the secondary sides of inverters by eliminating harmonic components

Accurately measure the fundamental wave alone by eliminating harmonic components with the DMM’s low-pass filter function.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure ripple voltage of DC charging systems

Measure ripple voltage with a superposed DC signal by using peak value measurement and DC + AC voltage measurement.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Percentage display for 4 to 20 mA instrumentation signals

The digital multimeters can convert and display instrumentation signals of 4 to 20 mA or 0 to 20 mA representing properties such as temperature, pressure, and flow rate from a transducer or other device that converts sensor data into an electrical signal.

 

 

 

 

 

 

 

 

600.00 μA range for measuring very low currents used by gas-burning devices

Accurately measure the very low currents such as burner flame currents.

 

 

 

Clamp-on sensor based current measurement eliminates the cause of accidents

Mistakenly measuring voltage using the current range may lead to a short-circuit. The DT4281 eliminates the root cause of such accidents by providing clamp-on sensor based current measurement functionality instead of using conventional probes.

 

 

 

True RMS measurement for accurate measurement of even distorted current waveforms

Digital multimeters implement two types of measurement: mean-value measurement and true RMS measurement. The two methods yield significantly different measurement results for current waveforms, which are often distorted. For accurate measurement, it is necessary to use an instrument with true RMS capability.

 

 

 

Measurement data can be downloaded to, reviewed on, and saved to a computer.

If you connect the DT4281 to a computer with the optional Communication Package DT4900-01, you can graph data stored in the instrument’s internal memory and display measurement results in real time on the computer. In addition, displayed measured values can be saved (in text format). *The computer and multimeter are electrically isolated by means of optical communications so that data can be sent without concern for electrical hazards.

 

 

 

 

Designed and manufactured in Japan to ensure high quality and guaranteed with a 3-year warranty for peace of mind

All development, design, and manufacturing processes for almost all Hioki digital multimeters are carried out at our Head Office in Nagano Prefecture. Some of the industry’s most advanced technological capabilities enable us to deliver products of the highest possible quality.

 

 

 

 

 

 

Safe measurement requires use of an instrument that suits the measurement location.

To ensure operators’ ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV). Using an instrument that does not satisfy the required safety level can lead to an electrical accident.

 

(DT4281)

 

DC voltage 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt.
AC voltage 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3)
DC + AC voltage 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3)
Resistance 60.000 Ω to 600.0 MΩ, 8 ranges, Basic accuracy: ±0.03 % rdg. ±2 dgt.
DC current 600.00 μA to 600.00 mA, 4 ranges
Basic accuracy: ±0.05 % rdg. ±5 dgt.
AC current 600.00 μA to 600.00 mA, 4 ranges
Basic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)
Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range)
AC Current (use with Clamp on probes) 10.00 A to 1000 A, 7 ranges
Add the Clamp on probe accuracy to Basic accuracy 40 - 65 Hz : ±0.6 % rdg. ±2 dgt. (True RMS, crest factor 3)
Peak DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)
AC V, DC/AC A measurement: 
Signal width 1 msec or more (single), 250 μsec or more (repeated)
C (capacitance) 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt.
Continuity Check Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more
Diode test Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages
Frequency AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)
99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt.
dB conversion Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages
Display dB conversion value of AC voltage (dBV)
Temperature (thermocouples) K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F) 
Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C
Other functions Filter function (Remove harmonic noise, use only at 600 VAC, 1000 VAC ranges), Display value hold, Auto hold, Max/Min value display, Sampling select, Relative display, Measurement memory (400 data), Auto-power save, USB communication (option), 4-20 mA % conversion
Display Main and sub displays: 5-digits LCD, max. 60000 digits
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s )
Power supply LR6 (AA) alkaline batteries × 4, Continuous use: 100 hours
Dimensions and mass 93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries)
Accessories Test Lead L9207-10 × 1, Instruction Manual × 1, LR6 Alkaline Battery × 4
SKU DT4281
Brand Hioki
Shipping Weight 0.3900kg
Shipping Width 0.084m
Shipping Height 0.052m
Shipping Length 0.174m

Be The First To Review This Product!

Help other Test Equipment Online users shop smarter by writing reviews for products you have purchased.

Write a product review


We Also Recommend


CARRYING CASE 3853

CARRYING CASE 3853

$29.55

8% OFF RRP $32.00
CARRYING CASE C0201

CARRYING CASE C0201

$73.61

MAGNETIC STRAP Z5020

MAGNETIC STRAP Z5020

$73.61

32% OFF RRP $107.80
CLAMP ON PROBE 9010-50

CLAMP ON PROBE 9010-50

$265.07

16% OFF RRP $316.80
CLAMP ON PROBE 9132-50

CLAMP ON PROBE 9132-50

$471.33

19% OFF RRP $585.20
CLAMP ON PROBE 9018-50

CLAMP ON PROBE 9018-50

$559.07

Conversion Adapter 9704

Conversion Adapter 9704

$58.49

DT4910  THERMOCOUPLES (K) -40 to 260 °C (-40 to 500 °F)
30% OFF RRP $92.85

Others Also Bought


DT4255 - Electrical DMM

DT4255 - Electrical DMM

$426.25

30% OFF RRP $608.92
DT4256 - General Electrical Use DMM
20% OFF RRP $437.50
DT4282 - High End General Use DMM

DT4282 - High End General Use DMM

$795.83

0% OFF RRP $799.00

More From This Category


A5 - APPA OPEN CLAMP MULTIMETER

A5 - APPA OPEN CLAMP MULTIMETER

$154.00

20% OFF RRP $193.00
Conversion Adapter 9704

Conversion Adapter 9704

$58.49

PARAMETERS PA3020

PARAMETERS PA3020

$43.16

50% OFF RRP $86.31
EazyVolt Plus - Voltage Tester LCD Display
8% OFF RRP $206.00
DT4255 - Electrical DMM

DT4255 - Electrical DMM

$426.25

30% OFF RRP $608.92
DT4252 - General Use DMM

DT4252 - General Use DMM

$326.26

30% OFF RRP $465.71
Hioki 3244-60

Hioki 3244-60

$90.00

40% OFF RRP $150.00
UT71A- Intelligent Digital Multimeter
50% OFF RRP $227.31