Hioki compact 1 or 2-channel data loggers feature a 60,000 data set/channel memory to measure temperature, humidity, voltage or instrumentation signals. The LR5001 logs temperature and humidity over 2 channels in as fast as 1 second intervals.
Key Features
• Easily mount the light-weight , pocket-sized loggers in tight spaces
• Easy-to-see dual display
• Transfer data to PC even during recording
• Replace batteries while recording (30 second limit) Note: Recording is interrupted during battery replacement if the battery is very weak. After batteries are replaced, recording resumes automatically. Previously recorded data is not lost during battery replacement.
• 7 times the memory capacity than predecessor (Record 60,000 data per channel)
• Record without missing fluctuations in STAT mode • Measurement data is preserved even after the battery dies
• Worry-free backup preserves recorded data even if a new measurement is started by mistake
| Measurement items | Temperature 1 ch and Humidity 1 ch (Requires included or optional humidity sensor) |
|---|---|
| Measurement range | Temperature: -40.0 to 85.0 °C, Humidity: 0 to 100 % rh *at sensor environment |
| Basic accuracy | [Temperature] : ±0.5 °C (main unit + sensor accuracy, at 0.0 to 35.0 °C) [Humidity] : ±5 %rh (main unit + temperature / humidity sensor LR950x combination, at 20 to 30 °C / 10 to 50 % rh) Note: Basic accuracy is typical value, refer to the detailed catalog |
| Storage capacity | Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data |
| Recording interval | 1 to 30 sec., 1 to 60 min., 15 selections |
| Recording modes | Instantaneous recording: at every recording interval Statistical value recording: Measure atone second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval |
| Recording methods | One-time recording: Stop recording when the memory capacity is full Endless recording: Continue recording even when the memory capacity is full (old data is overwritten) Start: Logger button operation or scheduled time Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording) |
| Other functions | Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low Note: After batteries are replaced within 30 seconds, recording resumes automatically (Recording is interrupted during battery replacement) |
| Waterproof and dust-proof | IP54 (EN60529) (with sensor connected, but not including sensor tip) |
| Interfaces | Infrared optical communications with LR5091, LR5092-20 |
| Power supply | LR6 (AA) Alkaline battery × 1, Battery life: Approx. 3 months (Instantaneous recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 20 days (Instantaneous recording, with 1-second interval at 20 °C) |
| Dimensions and mass | 79 mm (3.11 in) W × 57 mm (2.246 in) H × 28 mm (1.10 in) D, 105 g (3.7 oz) |
| Accessories | LR6 (AA) Alkaline battery (built-in internal) × 1, Humidity Sensor LR9504 × 1, Instruction manual × 1, Operation guide × 1, Kickstand × 1 |
(LR5011)
| Measurement items | Temperature 1ch (with optional sensor) |
|---|---|
| Measurement range | -40.0 °C to 180.0 °C *Depends on measurement range of sensor |
| Basic accuracy | ±0.5 °C (main unit + sensor accuracy, at 0.0 to 35.0 °C) Note: Basic accuracy is typical value, refer to the detailed catalog |
| Storage capacity | Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data |
| Recording interval | 1 to 30 sec., 1 to 60 min., 15 selections |
| Recording modes | Instantaneous recording: at every recording interval Statistical value recording: Measure atone second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval |
| Recording methods | One-time recording: Stop recording when the memory capacity is full Endless recording: Continue recording even when the memory capacity is full (old data is overwritten) Start: Logger button operation or scheduled time Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording) |
| Other functions | Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low; guarantees approx. 30 sec. of recording operation and clock while battery is replaced |
| Waterproof and dust-proof | IP54 (EN60529) (with sensor connected, but not including sensor tip) |
| Interfaces | Infrared optical communications with LR5091, LR5092-20 |
| Power supply | LR6 (AA) Alkaline battery × 1, Battery life: Approx. 2 years (Instantaneous recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 2 months (Instantaneous recording, with 1-second interval at 20 °C) |
| Dimensions and mass | 79 mm (3.11 in) W × 57 mm (2.246 in) H × 28 mm (1.10 in) D, 105 g (3.7 oz) |
| Accessories | LR6 (AA) Alkaline battery (built-in internal) × 1, Instruction manual × 1, Operation guide × 1, Kickstand × 1 |
| Measurement items | Temperature 1 ch and Humidity 1 ch (Requires included or optional humidity sensor) |
|---|---|
| Measurement range | Temperature: -40.0 to 85.0 °C, Humidity: 0 to 100 % rh *at sensor environment |
| Basic accuracy | [Temperature] : ±0.5 °C (main unit + sensor accuracy, at 0.0 to 35.0 °C) [Humidity] : ±5 %rh (main unit + temperature / humidity sensor LR950x combination, at 20 to 30 °C / 10 to 50 % rh) Note: Basic accuracy is typical value, refer to the detailed catalog |
| Storage capacity | Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data |
| Recording interval | 1 to 30 sec., 1 to 60 min., 15 selections |
| Recording modes | Instantaneous recording: at every recording interval Statistical value recording: Measureatone second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval |
| Recording methods | One-time recording: Stop recording when the memory capacity is full Endless recording: Continue recording even when the memory capacity is full (old data is overwritten) Start: Logger button operation or scheduled time Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording) |
| Other functions | Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low Note: After batteries are replaced within 30 seconds, recording resumes automatically (Recording is interrupted during battery replacement) |
| Waterproof and dust-proof | IP54 (EN60529) (with sensor connected, but not including sensor tip) |
| Interfaces | Infrared optical communications with LR5091, LR5092-20 |
| Power supply | LR6 (AA) Alkaline battery × 1, Battery life: Approx. 3 months (Instantaneous recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 20 days (Instantaneous recording, with 1-second interval at 20 °C) |
| Dimensions and mass | 79 mm (3.11 in) W × 57 mm (2.246 in) H × 28 mm (1.10 in) D, 105 g (3.7 oz) |
| Accessories | LR6 (AA) Alkaline battery (built-in internal) × 1, Humidity Sensor LR9504 × 1, Instruction manual × 1, Operation guide × 1, Kickstand × 1 |
| SKU | LR5011 |
| Brand | Hioki |
| Shipping Weight | 0.1050kg |
Be The First To Review This Product!
Help other Test Equipment Online users shop smarter by writing reviews for products you have purchased.